Safety Testing System / Electrical Safety Testing System for Fan
1. Features:
2. Technical parameters:
AC Hipot | |
Output voltage setting range/precision | AC 200~5000V ±(3%*setting value + 5 digit) |
Breakdown current measuring range/precision | 0.10~99.99mA ±(3%*displayed value + 5 digit) |
Presetting breakdown current alarm range/precision | Up limit: 0.10~99.99mA; Lower limit: 0.00~5.00mA |
Testing time range/resolution | 1~300S 1s/step |
Insulation resistance | |
Output voltage setting range/precision | DC 500/1000V ±(3%*displayed value + 5 digit) |
Insulation resistance measuring range/precision | 1~2000MΩ Within 100MΩ: ±(5%*displayed value + 3 digit); Above 100MΩ: ±(8%*displayed value + 8 digit); |
Presetting insulation resistance alarm range/precision | Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ |
Testing time range/resolution | 1-300s 1s/step |
Grounding | |
Ground current output range/precision | AC 5.0~30.0A ±(3%*setting value + 5 digit) |
Ground resistance measuring range/precision | 10.0~600mΩ±(3%*displayed value + 5 digit) |
Presetting ground resistance alarm range | Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ Lower limit: 0.0 ~100mΩ |
Testing time/resolution | 1~60s 1s/step |
Leakage current | |
Output voltage | 1.06 times of nominal voltage |
Output voltage measuring range/precision | AC 50~280V ±(0.5%*displayed value + 2 digit) |
Leakage current measuring range/precision | 0.05~20.00mA ±(3%*displayed value +0.02mA) |
Presetting leakage current alarm range | Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA |
Testing time range/resolution | 1~300s 1s/step |
power | |
Output voltage | Equals input voltage |
Output voltage measuring range/precision | AC 50~280V ±(0.5%*displayed value + 2 digit) |
Output current measuring range/precision | AC 0.20~30.00A ±(0.5%*displayed value + 2 digit) |
Power measuring range/precision | 30~6000W ±(0.5%*displayed value + 5 digit) |
Presetting power alarm range | Up limit: 30~6000W; Lower limit: 0~6000W |
Testing time/resolution | 1~300s 1s/step |
Low voltage starts | |
Output voltage | O.85 times of input voltage |
Output voltage measuring range/precision | AC 50~280V ±(0.5%*displayed value + 2 digit) |
Starting current measuring range/precision | AC 0.20~30.00A ±(0.5%*displayed value + 2 digit) |
Presetting current alarm range | Up limit: 0.20~30.00A; Lower limit: 0.00~25.00A |
Testing time/resolution | 1~300s 1s/step |
3. About electrical safety testing:
4. Image of tested object:
5. Image of electrical safety testing system