Add to Cart
Air Conditioner Motor Testing Machine, Motor Of Air Conditioner Indoor Unit
1. Product specification and test:
1.1 Station: two stations
1.2 Clamping mode: standard equipped with 8-bit clamps
1.3 Test: Low-voltage, no-load, stall, rotation, Hipot, surge, insulation resistance and winding resistance
2. Technical parameters:
2.1 Low voltage start:
| voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 words) | 
| current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) | 
| power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) | 
2.2 No-load:
| voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) | 
| current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) | 
| power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) | 
2.3 Stall
| voltage testing range and precision | AC:30~500V ±(0.5%×display value+1 word) | 
| current testing range and precision | AC:0.02~5.0A ±(0.5%×display value+2 words) | 
| power testing range and precision | 0.6-1500W ±(0.5%×display value+5 words) | 
2.4 Direction of rotation
| rotation mode: Hall/MAC/inductance | |
| rotation | CW, CCW, still | 
2.5 AC Hipot:
| Output voltage setting range and precision | AC 500~3000V ±(2%×setting value+10V) | 
| breakdown current testing range/precision | 0.10~20.00mA ±(2%×setting value+0.05 mA) | 
| Hipot current presetting alarm range | Max:0.10~20.00mA;Min:0.00~20.00mA | 
| Hipot current/resolution | ±(2% display value+0.05 mA);0.01 mA | 
| test time range/resolution | 0.5~999.9s 0.1s/step | 
| Arc detection | 0~9 level | 
2.6 Surge:
| output voltage setting range/precision | 500~3000V ±(3%×setting value+8V) | 
| sampling frequency | 100MHz | 
| waveform comparison | area, area difference, corona and phase 3 waveforms displayed in the testing interface | 
2.7 Insulation Resistance:
| output voltage setting range/precision | DC 500V/1000V ±(2%×setting value+10V) | 
| insulation resistance testing range/precision | 
			 1~500MΩ ≤100MΩ:±(3%×setting value+0.5MΩ) ;>100 MΩ:±(5%×setting value+5MΩ)  | 
		
| insulation resistance alarm setting range | Max: 0~500MΩ; Min: 1~100MΩ | 
| test time range/resolution | 0.5~999s 0.1s/step | 
2.8 DC Winding resistance :
| testing range and precision | 10.0mΩ~2KΩ ±(0.3%×display value+3 words) temperature compensation can be set. | 
| test time range/resolution | 
			 0.5~20s 0.1s/step 
  | 
		
| temperature compensation function | Yes | 
| temperature probe/range | DS18b20 -10.0℃~+50.0℃ | 
| precision | ±0.5°C(range: -10℃~+50℃) | 
3. Service